- Date
- 06/06/2019
- W/O
- 766519
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00578
- PipeID
- P18498
- Time
- 11:53 PM
- Certificate
- U-111-11880
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K6553
- Sewer Name
- 14 TRUNK "B"
- City
- LANCASTER
- Loc. details
- Easement/Right of Way
- Location Code
- D
- Use of Sewer
- Sanitary Sewer
- District
- District 14
- Page No.
- 07
- Purpose
- Routine Assessment
- Project
- WO_766519_TV14078_MAY2019
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 18 in.
- Width
- 18 in.
- Upstream MH
- 14 0415
- Downstream MH
- 14 0414
- Dir. of Survey
- Downstream
- Length Surveyed
- 389.6 ft.
- Total Length
- 389.6 ft.
- Structural Index
- 3
- Structural Quick
- 5C3N
- Structural Rating
- 490
- O&M Index
- 2
- O&M Quick
- 412N
- O&M Rating
- 158
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 648
Pipe schematic from manhole 14 0415 to 14 0414 Observation photos (4)

2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

2 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

17.6 ft. - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

307.4 ft. - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: YES