Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 28, 2019, 11:00 AM
  • 15 0060_15 0059A_05282019_040044.mp4

Date
05/28/2019
W/O
766535
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00622
PipeID
P11954
Time
4:00 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6544
Sewer Name
15 PUENTE TRUNK
City
INDUSTRY
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
35
Purpose
Routine Assessment
Project
WO_766535_TV15220_MAY2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
15 0059A
Downstream MH
15 0060
Dir. of Survey
Upstream
Length Surveyed
12.9 ft.
Total Length
12.9 ft.
Structural Index
4
Structural Quick
4131
Structural Rating
7
O&M Index
3
O&M Quick
4122
O&M Rating
8
Overall Index
3
Overall Quick
Overall Rating
15
Pipe schematic from manhole 15 0059A to 15 0060
MH: 15 0059AMH: 15 0060upstream0 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 3 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Ends - 15 00600.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish4 ft. FM - Fracture Multiple, from 04 to 07 o'clock, within 8 inches of joint: YES8.1 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES10.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start12.9 ft. AMH - Downstream Manhole, Survey Begins - 15 0059A12.9 ft. MWM - Water Mark, 50 %of cross sectional area12.9 ft. MWL - Water Level, 5 %of cross sectional area12.9 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 9 O'CLOCK

Observation photos (3)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    4.8 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 04 to 07 o'clock, within 8 inches of joint: YES

    8.9 ft. - Fracture Multiple, from 04 to 07 o'clock, within 8 inches of joint: YES

Observations (10)

DistanceCodeObservation
0AMH15 0059A
12.4DAGS
4.8CM
12.9MGOACTIVE CONNECTION AT MH 3 O'CLOCK
8.9FM
0MWM
12.9AMH15 0060
0MWL
2DAGS
0MGOACTIVE CONNECTION AT MH 9 O'CLOCK

Properties (6)

additional_info
SC378159
custom_field_two
3
customer
LACSD
datetime
2019-05-28T04:00:48-07:00
documentation
PRO PIPE
is_lateral_inspection
false