Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 19, 2018, 09:11 AM
  • 02 1922_02 1921_07122018_165643.mp4

Date
09/19/2018
W/O
723786
Weather
Dry
Operator/Surveyor
B. FUGATE
Sewer ID
Z00238
PipeID
P04270
Time
2:11 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6108
Sewer Name
02 BELVEDERE TRUNK
City
EAST LOS ANGELES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
05
Purpose
Routine Assessment
Project
RFIR_WO_723786_TV02239_SEP2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
02 1921
Downstream MH
02 1922
Dir. of Survey
Upstream
Length Surveyed
198.5 ft.
Total Length
198.5 ft.
Structural Index
3
Structural Quick
423G
Structural Rating
125
O&M Index
3
O&M Quick
3121
O&M Rating
5
Overall Index
3
Overall Quick
Overall Rating
130
Pipe schematic from manhole 02 1921 to 02 1922
MH: 02 1921MH: 02 1922upstream0 ft. AMH - Upstream Manhole, Survey Ends - 02 19220 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish7.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"32.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"37.2 ft. FM - Fracture Multiple, from 07 to 12 o'clock, within 8 inches of joint: YES62.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"84.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"84.8 ft. RMC - Roots Medium Connection, from 07 to 10 o'clock, 15 %, within 8 inches of joint: NO84.8 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: NO, 6"86.8 ft. RFB - Roots Fine Barrell, from 07 to 12 o'clock136.4 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"154.4 ft. FM - Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES185.7 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"194.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start198.5 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK198.5 ft. MWL - Water Level, 10 %of cross sectional area198.5 ft. MWM - Water Mark, 15 %of cross sectional area198.5 ft. AMH - Downstream Manhole, Survey Begins - 02 1921

Observations (18)

DistanceCodeObservation
198.5AMH02 1922
161.3FM
0MGOCONNECTION AT MH 9 O'CLOCK
135.7TF
165.9TF
111.7RFB
44.1FM
0MWL
113.7RMC
12.8TF
191.1TF
113.7TF
62.1TFA
114.2TFC
3.9CM
198.5CM
0MWM
0AMH02 1921

Properties (6)

additional_info
SC364824
custom_field_two
3
customer
LACSD
datetime
2018-09-19T02:11:00-07:00
documentation
PROPIPE
is_lateral_inspection
false