Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 5, 2018, 06:26 AM
  • 02 2036A_02 1320_04092018_234232.mp4

Date
09/04/2018
W/O
723786
Weather
Dry
Operator/Surveyor
B. FUGATE
Sewer ID
Z00238
PipeID
P03841
Time
11:26 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K5994
Sewer Name
02 BELVEDERE TRUNK
City
EAST LOS ANGELS
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
08
Purpose
Routine Assessment
Project
RFIR_WO_723786_TV02239_SEP2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
02 2036A
Downstream MH
02 1320
Dir. of Survey
Downstream
Length Surveyed
329.2 ft.
Total Length
329.2 ft.
Structural Index
3
Structural Quick
3L00
Structural Rating
201
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
201
Pipe schematic from manhole 02 2036A to 02 1320
MH: 02 2036AMH: 02 1320downstream0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. MWM - Water Mark, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 2063A0 ft. MWL - Water Level, 5 %of cross sectional area3.8 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start91 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"108.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"152.6 ft. FS - Fracture Spiral, from 02 to 05 o'clock, within 8 inches of joint: YES189.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"199.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"224.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"299.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"316.7 ft. H - Hole, at 10 o'clock, within 8 inches of joint: NO329.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish329.2 ft. AOC - Drop Connection, Survey Ends - 02 1320

Observations (16)

DistanceCodeObservation
0MGOCONNECTION AT MH 3 O'CLOCK
316.7H
299.9TFC
329.2CM
0MGOCONNECTION AT MH 9 O'CLOCK
0MWM
224.2TF
152.6FS
329.2AOC02 1320
199.1TF
0AMH02 2063A
3.8CM
91TF
189.3TF
0MWL
108.6TF

Properties (6)

additional_info
SC364808
custom_field_two
2
customer
LACSD
datetime
2018-09-04T23:26:00-07:00
documentation
PROPIPE
is_lateral_inspection
false