Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 5, 2018, 07:08 AM
  • 02 1317_02 1316_05092018_001626.mp4

Date
09/05/2018
W/O
723786
Weather
Dry
Operator/Surveyor
B. FUGATE
Sewer ID
Z00238
PipeID
P03837
Time
12:08 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K5994
Sewer Name
02 BELVEDERE TRUNK
City
EAST LOS ANGELES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
08
Purpose
Routine Assessment
Project
RFIR_WO_723786_TV02239_SEP2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
02 1317
Downstream MH
02 1316
Dir. of Survey
Downstream
Length Surveyed
190.2 ft.
Total Length
190.2 ft.
Structural Index
3
Structural Quick
4331
Structural Rating
19
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
19
Pipe schematic from manhole 02 1317 to 02 1316
MH: 02 1317MH: 02 1316downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 13172.1 ft. FM - Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES22.3 ft. CM - Crack Multiple, from 09 to 11 o'clock, within 8 inches of joint: YES70.1 ft. FC - Fracture Circumferential, from 01 to 05 o'clock, within 8 inches of joint: YES126.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"137.8 ft. CL - Crack Longitudinal, at 05 o'clock, within 8 inches of joint: YES160.3 ft. FM - Fracture Multiple, from 09 to 11 o'clock, within 8 inches of joint: YES190.2 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES190.2 ft. AMH - Downstream Manhole, Survey Ends - 02 1316

Observations (11)

DistanceCodeObservation
2.1FM
160.3FM
190.2FM
0MWL
70.1FC
22.3CM
190.2AMH02 1316
0MWM
137.8CL
126.7TFC
0AMH02 1317

Properties (6)

additional_info
SC364808
custom_field_two
3
customer
LACSD
datetime
2018-09-05T00:08:00-07:00
documentation
PROPIPE
is_lateral_inspection
false