Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 5, 2018, 10:34 AM
  • 02 1301_02 1300_05092018_034456.mp4

Date
09/05/2018
W/O
723786
Weather
Dry
Operator/Surveyor
B. FUGATE
Sewer ID
Z00238
PipeID
P03818
Time
3:34 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K5994
Sewer Name
02 BELVEDERE TRUNK
City
EAST LOS ANGELES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
12
Purpose
Routine Assessment
Project
RFIR_WO_723786_TV02239_SEP2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
02 1300
Downstream MH
02 1301
Dir. of Survey
Upstream
Length Surveyed
219.3 ft.
Total Length
219.3 ft.
Structural Index
3
Structural Quick
3H00
Structural Rating
129
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
129
Pipe schematic from manhole 02 1300 to 02 1301
MH: 02 1300MH: 02 1301upstream0 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish0 ft. AMH - Upstream Manhole, Survey Ends - 02 130120.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"35.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"63.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6", 4"66.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6", 4"74.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"79 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"111.5 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"114.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"119.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"180.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"188.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"193.2 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"215.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start219.3 ft. MWM - Water Mark, 20 %of cross sectional area219.3 ft. MWL - Water Level, 10 %of cross sectional area219.3 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK219.3 ft. AMH - Downstream Manhole, Survey Begins - 02 1300

Observations (19)

DistanceCodeObservation
3.9CM
0MWM
145.1TF
153.1TF
219.3CM
140.3TF
104.5TF
30.9TFC
219.3AMH02 1301
0MWL
38.8TF
99.8TFC
198.8TF
155.5TF
0MGOCONNECTION AT MH 9 O'CLOCK
107.8TB
26.1TB
0AMH02 1300
183.5TF

Properties (6)

additional_info
SC364808
custom_field_two
3
customer
LACSD
datetime
2018-09-05T03:34:00-07:00
documentation
PROPIPE
is_lateral_inspection
false