Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 5, 2018, 10:10 AM
  • 02 1299_02 1298_05092018_032554.mp4

Date
09/05/2018
W/O
723786
Weather
Dry
Operator/Surveyor
B. FUGATE
Sewer ID
Z00238
PipeID
P03816
Time
3:10 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K5994
Sewer Name
02 BELVEDERE TRUNK
City
EAST LOS ANGELES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
12
Purpose
Routine Assessment
Project
RFIR_WO_723786_TV02239_SEP2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
02 1299
Downstream MH
02 1298
Dir. of Survey
Downstream
Length Surveyed
381.4 ft.
Total Length
381.4 ft.
Structural Index
3
Structural Quick
3N00
Structural Rating
225
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
225
Pipe schematic from manhole 02 1299 to 02 1298
MH: 02 1299MH: 02 1298downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 12990 ft. MWL - Water Level, 5 %of cross sectional area4.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start78.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"82.9 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"104.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"107.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"135.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"135.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"148 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"183 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"184 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"186.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"188.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"219.1 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"222 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"231.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"262.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"267.9 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"272.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"306.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"306.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"306.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"351.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"381.4 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK381.4 ft. AMH - Downstream Manhole, Survey Ends - 02 1298381.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observations (28)

DistanceCodeObservation
135.1TF
351.6TF
381.4MGOCONNECTION AT MH 9 O'CLOCK
148TF
183TB
222TB
78.9TF
184TB
272.6TF
4.6CM
381.4AMH02 1298
306.4TF
186.4TFC
188.4TFC
231.7TFC
306.4TFC
0MWM
107.3TFC
381.4CM
104.1TFC
267.9TB
262.1TF
135.1TFC
0AMH02 1299
219.1TB
306.4TF
82.9TB
0MWL

Properties (6)

additional_info
SC364808
custom_field_two
3
customer
LACSD
datetime
2018-09-05T03:10:00-07:00
documentation
PROPIPE
is_lateral_inspection
false