Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 7, 2019, 07:00 AM
  • 2_1_1_07052019_002748.mp4

Date
05/07/2019
W/O
761425
Weather
Dry
Operator/Surveyor
E.RUIZ
Sewer ID
Z00140
PipeID
P09822
Time
12:00 AM
Certificate
U-715-07000753
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6532
Sewer Name
C JOINT OUTFALL C - UNIT 8B
City
HAWAIIAN GARDENS
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 19
Page No.
09
Purpose
Routine Assessment
Project
WO_761425_TV19020_APR2019
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
39 in.
Width
39 in.
Upstream MH
C 0359
Downstream MH
C 0358
Dir. of Survey
Downstream
Length Surveyed
853.2 ft.
Total Length
853.2 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole C 0359 to C 0358
MH: C 0359MH: C 0358downstream0 ft. AMH - Upstream Manhole, Survey Begins - C 03590 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MWL - Water Level, 40 %of cross sectional area0 ft. MGO - General Observation - CONNECTION IN MH 3 OCLOCK15.5 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start15.9 ft. MGO - General Observation - MAG COAT THROUGHOUT PIPE580 ft. IS - Infiltration Stain, at 11 o'clock, within 8 inches of joint: YES849.9 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish853.2 ft. AMH - Downstream Manhole, Survey Ends - C 0358853.2 ft. MGO - General Observation - INFILTRATION STAINS IN MH

Observation photos (3)

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    15.5 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • General Observation - MAG COAT THROUGHOUT PIPE

    15.9 ft. - General Observation - MAG COAT THROUGHOUT PIPE

  • Infiltration Stain, at 11 o'clock, within 8 inches of joint: YES

    580 ft. - Infiltration Stain, at 11 o'clock, within 8 inches of joint: YES

Observations (10)

DistanceCodeObservation
0AMHC 0359
0MWM
15.5SAP
15.9MGOMAG COAT THROUGHOUT PIPE
853.2AMHC 0358
0MWL
580IS
0MGOCONNECTION IN MH 3 OCLOCK
853.2MGOINFILTRATION STAINS IN MH
849.9SAP

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2019-05-07T00:00:53-07:00
documentation
PROPIPE
is_lateral_inspection
false