Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 7, 2019, 04:25 AM
  • 4_1_3_06052019_222413.mp4

Date
05/06/2019
W/O
761425
Weather
Dry
Operator/Surveyor
E.RUIZ
Sewer ID
Z00140
PipeID
P09824
Time
9:25 PM
Certificate
U-715-07000753
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6532
Sewer Name
C JOINT OUTFALL C - UNIT 8B
City
HAWAIIAN GARDENS
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 19
Page No.
07
Purpose
Routine Assessment
Project
WO_761425_TV19020_APR2019
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
39 in.
Width
39 in.
Upstream MH
C 0361
Downstream MH
C 0360
Dir. of Survey
Downstream
Length Surveyed
691.9 ft.
Total Length
691.9 ft.
Structural Index
3
Structural Quick
3Y00
Structural Rating
393
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
397
Pipe schematic from manhole C 0361 to C 0360
MH: C 0361MH: C 0360downstream0 ft. MWL - Water Level, 35 %of cross sectional area0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - C 036115 ft. MGO - General Observation - MAG COAT THROUGHOUT PIPE35 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start666.4 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 10"666.4 ft. LL - Alignment Left, 30 %691.9 ft. AMH - Downstream Manhole, Survey Ends - C 0360691.9 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish

Observation photos (2)

  • General Observation - MAG COAT THROUGHOUT PIPE

    15 ft. - General Observation - MAG COAT THROUGHOUT PIPE

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    35 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (9)

DistanceCodeObservation
35SAP
691.9AMHC 0360
15MGOMAG COAT THROUGHOUT PIPE
0MWL
0MWM
691.9SAP
0AMHC 0361
666.4TFA
666.4LL

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2019-05-06T21:25:58-07:00
documentation
PROPIPE
is_lateral_inspection
false