Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 7, 2019, 05:25 AM
  • 3_1_1_06052019_224314.mp4

Date
05/06/2019
W/O
761425
Weather
Dry
Operator/Surveyor
E.RUIZ
Sewer ID
Z00140
PipeID
P09823
Time
10:25 PM
Certificate
U-715-07000753
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6532
Sewer Name
C JOINT OUTFALL C - UNIT 8B
City
HAWAIIAN GARDENS
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 19
Page No.
09
Purpose
Routine Assessment
Project
WO_761425_TV19020_APR2019
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
39 in.
Width
39 in.
Upstream MH
C 0360
Downstream MH
C 0359
Dir. of Survey
Downstream
Length Surveyed
491.9 ft.
Total Length
491.9 ft.
Structural Index
3
Structural Quick
3R00
Structural Rating
288
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
288
Pipe schematic from manhole C 0360 to C 0359
MH: C 0360MH: C 0359downstream0 ft. MWL - Water Level, 40 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - C 03600 ft. MWM - Water Mark, 40 %of cross sectional area5.8 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start5.8 ft. MGO - General Observation - MAG COAT THROUGHOUT PIPE401.1 ft. IS - Infiltration Stain, at 11 o'clock, within 8 inches of joint: YES488.2 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish491.9 ft. MGO - General Observation - CONNECTION IN MH 3 OCLOCK491.9 ft. AMH - Downstream Manhole, Survey Ends - C 0359

Observation photos (3)

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    5.8 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • General Observation - MAG COAT THROUGHOUT PIPE

    5.8 ft. - General Observation - MAG COAT THROUGHOUT PIPE

  • Infiltration Stain, at 11 o'clock, within 8 inches of joint: YES

    401.1 ft. - Infiltration Stain, at 11 o'clock, within 8 inches of joint: YES

Observations (9)

DistanceCodeObservation
0MWL
5.8SAP
5.8MGOMAG COAT THROUGHOUT PIPE
0AMHC 0360
491.9MGOCONNECTION IN MH 3 OCLOCK
0MWM
488.2SAP
401.1IS
491.9AMHC 0359

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2019-05-06T22:25:12-07:00
documentation
PROPIPE
is_lateral_inspection
false