Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 22, 2019, 06:54 PM
  • 05 1343_05 1342_8222019_120635.mp4

Date
08/22/2019
W/O
0786986
Weather
Dry
Operator/Surveyor
FRANKLIN
Sewer ID
Z00238
PipeID
P03868
Time
11:54 AM
Certificate
U-415-06024039
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G8062
Sewer Name
02 BELVEDERE TRUNK
City
EAST LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
08
Purpose
Routine Assessment
Project
20190820DF_BELVEDERE_TRUNK
Material
NRCP
Shape
Circular
Height
15 in.
Upstream MH
05 1343
Downstream MH
05 1342
Dir. of Survey
Downstream
Length Surveyed
272.6 ft.
Total Length
272.6 ft.
Structural Index
2
Structural Quick
3122
Structural Rating
7
O&M Index
3
O&M Quick
3121
O&M Rating
5
Overall Index
2
Overall Quick
Overall Rating
12
Pipe schematic from manhole 05 1343 to 05 1342
MH: 05 1343MH: 05 1342downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 11:58 AM0 ft. MGO - General Observation - Conn. @ Mh, 6 O' Clock. OPEN0 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active0 ft. MWM - Water Mark, 20 %of cross sectional area2 ft. SZ - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - 20% MAG2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start13.5 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start16.7 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish17.3 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start25.9 ft. MGP - General Photograph65.3 ft. MGP - General Photograph77.8 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 4" - Open101.2 ft. MGP - General Photograph179.8 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: YES, 4"229.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES231.4 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: YES, 4"272 ft. MGP - General Photograph272 ft. MGP - General Photograph272 ft. OBZ - Obstacles Other, 20 %of cross sectional area, from 09 to 04 o'clock - ROD/STICK272.6 ft. MSA - Survey Abandoned - ROD/STICK272.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish272.6 ft. SZ - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - 20% MAG272.6 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (12)

  • Upstream Manhole, Survey Begins - 11:58 AM

    0 ft. - Upstream Manhole, Survey Begins - 11:58 AM

  • Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - 20% MAG

    2 ft. - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - 20% MAG

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

    13.5 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    17.3 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Photograph

    25.9 ft. - General Photograph

  • General Photograph

    65.3 ft. - General Photograph

  • General Photograph

    101.2 ft. - General Photograph

  • Deposits Attached Grease, 5 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: YES

    229.6 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES

  • General Photograph

    272 ft. - General Photograph

  • General Photograph

    272 ft. - General Photograph

  • Obstacles Other, 20 %of cross sectional area, from 09 to 04 o'clock - ROD/STICK

    272 ft. - Obstacles Other, 20 %of cross sectional area, from 09 to 04 o'clock - ROD/STICK

Observations (24)

DistanceCodeObservation
2SZ20% MAG
179.8TFA
77.8TFOpen
229.6DAGS
272.6MSAROD/STICK
272.6CM
272.6SZ20% MAG
272MGP
101.2MGP
272MGP
272.6SSS
17.3SSS
65.3MGP
13.5CL
16.7CL
0MWL
272OBZROD/STICK
231.4TFA
0AMH11:58 AM
0MGOConn. @ Mh, 6 O' Clock. OPEN
2CM
0MGOConn. @ Mh, 3 O' Clock. Active
0MWM
25.9MGP

Properties (6)

additional_info
ONSCREEN TAPE NUMBER IS WRONG. CORRECT TAPE IS (G8062)
custom_field_two
5
customer
LACSD
datetime
2019-08-22T11:54:42-07:00
documentation
FRANKLIN, CASTILLO, IGNACIO
is_lateral_inspection
false