Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 20, 2019, 06:38 PM
  • 02 1916_02 1346B_8202019_114204.mp4

Date
08/20/2019
W/O
0786986
Weather
Dry
Operator/Surveyor
FRANKLIN
Sewer ID
Z00238
PipeID
P04620
Time
11:38 AM
Certificate
U-415-06024039
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G8060
Sewer Name
02 BELVEDERE TRUNK
City
EAST LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
08
Purpose
Routine Assessment
Project
20190820DF_BELVEDERE_TRUNK
Material
NRCP
Shape
Circular
Height
15 in.
Upstream MH
02 1346B
Downstream MH
02 1916
Dir. of Survey
Upstream
Length Surveyed
108.2 ft.
Total Length
108.2 ft.
Structural Index
3
Structural Quick
3221
Structural Rating
8
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
8
Pipe schematic from manhole 02 1346B to 02 1916
MH: 02 1346BMH: 02 1916upstream0 ft. MGO - General Observation - Grease Throughout The Reach (5%)0 ft. AMH - Upstream Manhole, Survey Ends - 11:53 AM0 ft. MGO - General Observation - ROACHES @ MH1.2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish1.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish64.7 ft. MGP - General Photograph81.5 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish81.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start81.5 ft. MMC - Material Change, Vitrified clay pipe81.5 ft. MGP - General Photograph83.4 ft. MGP - General Photograph87.5 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 4"106.2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start106.2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start108.2 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. OPEN108.2 ft. AMH - Downstream Manhole, Survey Begins - 11:39 AM108.2 ft. MGO - General Observation - ROACHES @ MH108.2 ft. MWM - Water Mark, 20 %of cross sectional area108.2 ft. MWL - Water Level, 15 %of cross sectional area

Observation photos (7)

  • Downstream Manhole, Survey Begins - 11:39 AM

    0 ft. - Downstream Manhole, Survey Begins - 11:39 AM

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Photograph

    24.8 ft. - General Photograph

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    26.7 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Material Change, Vitrified clay pipe

    26.7 ft. - Material Change, Vitrified clay pipe

  • General Photograph

    26.7 ft. - General Photograph

  • General Photograph

    43.5 ft. - General Photograph

Observations (19)

DistanceCodeObservation
26.7SAV
2SSS
107SSS
0MGOConn. @ Mh, 3 O' Clock. OPEN
2SAV
0AMH11:39 AM
26.7CM
26.7MMC
108.2MGOGrease Throughout The Reach (5%)
20.7TFC
26.7MGP
0MGOROACHES @ MH
107CM
0MWM
108.2AMH11:53 AM
43.5MGP
0MWL
24.8MGP
108.2MGOROACHES @ MH

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2019-08-20T11:38:07-07:00
documentation
FRANKLIN, CASTILLO, RUVALCABA
is_lateral_inspection
false