Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 19, 2019, 05:52 PM
  • 05 2562_05 0480_8192019_105530.mp4

Date
08/19/2019
W/O
0786503
Weather
Dry
Operator/Surveyor
FRANKLIN
Sewer ID
Z00526
PipeID
P05696
Time
10:52 AM
Certificate
U-415-06024039
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G8059
Sewer Name
05 STRAWBERRY AVENUE TRUNK
City
HAWTHORNE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
13
Purpose
Routine Assessment
Project
20190819DF_STRAWBERRY_AVENUE_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Upstream MH
05 0480
Downstream MH
05 2562
Dir. of Survey
Upstream
Length Surveyed
43.5 ft.
Total Length
43.5 ft.
Structural Index
3
Structural Quick
3121
Structural Rating
5
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
5
Pipe schematic from manhole 05 0480 to 05 2562
MH: 05 0480MH: 05 2562upstream0 ft. AMH - Upstream Manhole, Survey Ends - 11:02 AM0 ft. MGO - General Observation - GREASE THROUGHOUT THE REACH (5%)0.5 ft. MGP - General Photograph0.5 ft. MGO - General Observation - STOP LOG DOWN @ 12 O'CLOCK1 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish15.7 ft. MGP - General Photograph16.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"19.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"31.1 ft. MGP - General Photograph41.5 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start41.5 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active41.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start43.5 ft. MWL - Water Level, 15 %of cross sectional area43.5 ft. MWM - Water Mark, 20 %of cross sectional area43.5 ft. AMH - Downstream Manhole, Survey Begins - 10:54 AM

Observation photos (5)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Photograph

    12.4 ft. - General Photograph

  • General Photograph

    27.8 ft. - General Photograph

  • General Observation - STOP LOG DOWN @ 12 O'CLOCK

    43 ft. - General Observation - STOP LOG DOWN @ 12 O'CLOCK

Observations (16)

DistanceCodeObservation
12.4MGP
26.7TFC
2SSS
0MWL
27.8MGP
43MGP
2MGOConn. @ Mh, 9 O' Clock. Active
2CM
42.5SSS
24TFC
0MWM
43MGOSTOP LOG DOWN @ 12 O'CLOCK
43.5AMH11:02 AM
43.5MGOGREASE THROUGHOUT THE REACH (5%)
42.5CM
0AMH10:54 AM

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2019-08-19T10:52:18-07:00
documentation
FRANKLIN, CASTILLO, RUVALCABA
is_lateral_inspection
false