C JOINT_C 0323_8212019_121509.mp4
0 ft. - Upstream Manhole, Survey Begins - 10:00 AM
2 ft. - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
2 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
2 ft. - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - 40% MAG
58.1 ft. - General Photograph
107.6 ft. - General Photograph
130.3 ft. - General Photograph
| Distance | Code | Observation |
|---|---|---|
| 156.9 | SRV | — |
| 157.9 | MGO | GREASE THROUGHOUT THE REACH (5%) |
| 2 | SRC | — |
| 0 | AMH | 10:00 AM |
| 156.9 | SSS | — |
| 2 | SRV | — |
| 2 | SAP | — |
| 0 | MWM | — |
| 157.9 | MGO | Peeling & Flaking Throughout The Reach |
| 2 | SSS | — |
| 130.3 | MGP | — |
| 58.1 | MGP | — |
| 156.9 | SRC | — |
| 107.6 | MGP | — |
| 156.9 | SAP | — |
| 157.9 | AMH | 12:31 PM |
| 0 | MWL | — |
| 156.9 | SZ | 40% MAG |
| 2 | SZ | 40% MAG |