Section#2_08 0470_08 0469__8202019__I0223.mp4
2 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG AREAS OF MISSING TILES
2 ft. - General Observation - 100% MISSING TILES START
2 ft. - General Observation - 80% MAG COAT START
2 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - CIRCUM & LONG REBAR
35 ft. - General Observation - 50% MAG COAT START
43.5 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - BROKEN REBAR
62.3 ft. - General Observation - 50% MISSING TILES
209.3 ft. - Water Mark, 80 %of cross sectional area
263.8 ft. - General Observation - 80% MAG COAT START
285.3 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - BROKEN REBAR
292.8 ft. - Surface Reinforcement Corroded, from 12 to 02 o'clock, within 8 inches of joint: NO - MISSING REBAR
313.2 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - BROKEN REBAR IN FLOW
334.6 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - BROKEN REBAR IN FLOW
339.3 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - CORRISON BEYOUND REBAR
377.2 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - BROKEN REBAR IN FLOW
378.3 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - CORRISIN BEYOUND REBAR
386.5 ft. - General Observation - 100% MISING TILES 10:00 TO 2:00
| Distance | Code | Observation |
|---|---|---|
| 339.3 | SRC | CORRISON BEYOUND REBAR |
| 15.6 | MGO | 30% MISSING TILES |
| 438.3 | MGO | 80% MAG COAT FINISH |
| 313.2 | SRC | BROKEN REBAR IN FLOW |
| 438.8 | AMH | 3:10AM |
| 2 | SAM | SEVERE AGG AREAS OF MISSING TILES |
| 2 | MGO | 100% MISSING TILES START |
| 0 | AMH | 2:35AM |
| 386.5 | MGO | 100% MISING TILES 10:00 TO 2:00 |
| 0 | MGO | MH CONN 9:00 ACTIVE |
| 35 | MGO | 100% MISSING TILES |
| 285.3 | SRC | BROKEN REBAR |
| 263.8 | MGO | 80% MAG COAT START |
| 0 | MGO | MH CONN 6:00 OPEN |
| 62.3 | MGO | 50% MISSING TILES |
| 0 | MWM | — |
| 377.2 | SRC | BROKEN REBAR IN FLOW |
| 2 | MGO | 80% MAG COAT START |
| 209.3 | MWL | — |
| 378.3 | SRC | CORRISIN BEYOUND REBAR |
| 35 | MGO | 50% MAG COAT START |
| 2 | SRC | CIRCUM & LONG REBAR |
| 438.3 | SRC | CORRISON BEYOUND REBAR |
| 292.8 | SRC | MISSING REBAR |
| 43.5 | SRC | BROKEN REBAR |
| 209.3 | MWM | — |
| 438.3 | MGO | 100% MISSING TILES FINISH |
| 334.6 | SRC | BROKEN REBAR IN FLOW |
| 0 | MWL | — |
| 438.3 | SRC | LONG & CIRCUM REBAR BROKEN MISSING |
| 438.3 | SAM | SEVERE AGG AREAS OF MISSING TILES |