- Date
- 08/21/2019
- W/O
- 0786985
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00238
- PipeID
- P03860
- Time
- 1:34 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- I0226
- Sewer Name
- 02 BELVEDERE TRUNK
- City
- LOS ANGLES
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 08
- Purpose
- Routine Assessment
- Project
- 20190821MDM_BELVEDERE_TRUNK
- Material
- NRCP
- Shape
- Circular
- Height
- 15 in.
- Upstream MH
- 02 1335
- Downstream MH
- 02 1336
- Dir. of Survey
- Upstream
- Length Surveyed
- 269.7 ft.
- Total Length
- 269.7 ft.
- Structural Index
- 3
- Structural Quick
- 4G3J
- Structural Rating
- 328
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 328
Pipe schematic from manhole 02 1335 to 02 1336 Observation photos (4)

2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

26.3 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG

74.6 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

110.5 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG