Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 16, 2015, 05:39 AM
  • 02 0225_02 0224_15092015_225008.mp4

Date
09/15/2015
W/O
521010
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00251
PipeID
P02531
Time
10:39 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K2746
Sewer Name
02 DOWNEY-BELLFLOWER TRUNK
City
DOWNEY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
27
Purpose
Routine Assessment
Project
WO_521010_TV02055_AUG2015
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
02 0225
Downstream MH
02 0224
Dir. of Survey
Downstream
Length Surveyed
166.4 ft.
Total Length
166.4 ft.
Structural Index
3
Structural Quick
3200
Structural Rating
6
O&M Index
1
O&M Quick
1100
O&M Rating
1
Overall Index
2
Overall Quick
Overall Rating
7
Pipe schematic from manhole 02 0225 to 02 0224
MH: 02 0225MH: 02 0224downstream0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 02250 ft. MWM - Water Mark, 35 %of cross sectional area5.7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES10.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start49 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"85 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"85.9 ft. RFJ - Roots Fine Joint, from 11 to 04 o'clock, within 8 inches of joint: YESR88.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"166.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish166.4 ft. MGO - General Observation - SERVICE LATERAL AT 9 O'CLOCK AT MH166.4 ft. AMH - Downstream Manhole, Survey Ends - 02 0224

Observations (12)

DistanceCodeObservation
49TB
166.4CM
85TFC
10.1CM
85.9RFJ
0MWL
5.7CM
0AMH02 0225
166.4MGOSERVICE LATERAL AT 9 O'CLOCK AT MH
166.4AMH02 0224
0MWM
88.1TF

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2015-09-15T22:39:42-07:00
documentation
PROPIPE
is_lateral_inspection
false