Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 15, 2015, 08:35 AM
  • 02 0243_02 0242_15092015_021209.mp4

Date
09/15/2015
W/O
521010
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00251
PipeID
P02551
Time
1:35 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K2745
Sewer Name
02 DOWNEY-BELLFLOWER TRUNK
City
DOWNEY
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
28
Purpose
Routine Assessment
Project
WO_521010_TV02055_AUG2015
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
02 0243
Downstream MH
02 0242
Dir. of Survey
Downstream
Length Surveyed
386.3 ft.
Total Length
386.3 ft.
Structural Index
3
Structural Quick
3523
Structural Rating
21
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
21
Pipe schematic from manhole 02 0243 to 02 0242
MH: 02 0243MH: 02 0242downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 02430 ft. MWM - Water Mark, 35 %of cross sectional area6.5 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES26.9 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES34.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES52.5 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"66.6 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES70.4 ft. CM - Crack Multiple, from 08 to 11 o'clock, within 8 inches of joint: YES79 ft. CM - Crack Multiple, from 03 to 04 o'clock, within 8 inches of joint: YES111.5 ft. CM - Crack Multiple, from 01 to 03 o'clock, within 8 inches of joint: YES119.1 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start157 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"245.3 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"358 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"379.6 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish386.3 ft. AMH - Downstream Manhole, Survey Ends - 02 0242

Observations (17)

DistanceCodeObservation
52.5TFC
0MWL
26.9CL
0AMH02 0243
119.1CM
6.5CL
245.3TFC
34.9CM
70.4CM
386.3AMH02 0242
0MWM
66.6CL
157TFC
79CM
379.6CM
358TFC
111.5CM

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2015-09-15T01:35:31-07:00
documentation
PROPIPE
is_lateral_inspection
false