Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 8, 2015, 10:49 AM
  • 02 0285_02 0284_08092015_035500.mp4

Date
09/08/2015
W/O
521010
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00251
PipeID
P02599
Time
3:49 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K2738
Sewer Name
02 DOWNEY-BELLFLOWER TRUNK
City
PICO RIVERA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
22
Purpose
Routine Assessment
Project
WO_521010_TV02055_AUG2015
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
02 0285
Downstream MH
02 0284
Dir. of Survey
Downstream
Length Surveyed
47.6 ft.
Total Length
47.6 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
5
Pipe schematic from manhole 02 0285 to 02 0284
MH: 02 0285MH: 02 0284downstream0 ft. MGO - General Observation - LATERAL AT MH 9 OCLOCK0 ft. MGO - General Observation - LATERAL AT MH 3 0CLOCK0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 02852.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Start18.4 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES, Start45.5 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish45.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Finish47.6 ft. MGO - General Observation - LATERAL AT MH 3 0CLOCK47.6 ft. AMH - Downstream Manhole, Survey Ends - 02 0284

Observations (11)

DistanceCodeObservation
0MGOLATERAL AT MH 9 OCLOCK
0MGOLATERAL AT MH 3 0CLOCK
45.5CM
2.2DAGS
0MWM
45.5DAGS
47.6MGOLATERAL AT MH 3 0CLOCK
0MWL
47.6AMH02 0284
18.4CM
0AMH02 0285

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2015-09-08T03:49:47-07:00
documentation
PROPIPE
is_lateral_inspection
false