Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 15, 2015, 11:03 AM
  • 02 0229A_02 0229_15092015_041401.mp4

Date
09/15/2015
W/O
521010
Weather
Light Rain
Operator/Surveyor
B.FUGATE
Sewer ID
Z00251
PipeID
P02536
Time
4:03 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K2745
Sewer Name
02 DOWNEY-BELLFLOWER TRUNK
City
DOWNEY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
27
Purpose
Routine Assessment
Project
WO_521010_TV02055_AUG2015
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
02 0229A
Downstream MH
02 0229
Dir. of Survey
Downstream
Length Surveyed
315 ft.
Total Length
315 ft.
Structural Index
3
Structural Quick
3221
Structural Rating
8
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
10
Pipe schematic from manhole 02 0229A to 02 0229
MH: 02 0229AMH: 02 0229downstream0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MGO - General Observation - SERVICE LATERAL AT 9 O'CLOCK AT MH0 ft. AMH - Upstream Manhole, Survey Begins - 02 0229A0 ft. MWL - Water Level, 10 %of cross sectional area4.6 ft. CM - Crack Multiple, from 11 to 03 o'clock, within 8 inches of joint: YES8.7 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES13 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES, Start92.2 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"95.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"187.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"191 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"275.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"279.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"301.3 ft. DSZ - Deposits Settled Other, 5 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES311.5 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish315 ft. MGO - General Observation - SERVICE LATERAL AT 3 O' CLOCK AT MH315 ft. AMH - Downstream Manhole, Survey Ends - 02 0229

Observations (17)

DistanceCodeObservation
0MWM
8.7CL
92.2TFA
13CM
4.6CM
279.2TFC
191TFC
311.5CM
187.8TF
95.6TFC
0MGOSERVICE LATERAL AT 9 O'CLOCK AT MH
301.3DSZ
315MGOSERVICE LATERAL AT 3 O' CLOCK AT MH
315AMH02 0229
0AMH02 0229A
0MWL
275.8TFC

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2015-09-15T04:03:06-07:00
documentation
PROPIPE
is_lateral_inspection
false