Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 16, 2015, 05:31 AM
  • 02 0226_02 0225_15092015_223800.mp4

Date
09/15/2015
W/O
521010
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00251
PipeID
P02532
Time
10:31 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K2746
Sewer Name
02 DOWNEY-BELLFLOWER TRUNK
City
DOWNEY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
27
Purpose
Routine Assessment
Project
WO_521010_TV02055_AUG2015
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
02 0226
Downstream MH
02 0225
Dir. of Survey
Downstream
Length Surveyed
97.8 ft.
Total Length
97.8 ft.
Structural Index
3
Structural Quick
3200
Structural Rating
6
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
6
Pipe schematic from manhole 02 0226 to 02 0225
MH: 02 0226MH: 02 0225downstream0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 02260 ft. MGO - General Observation - SERVICE LATERAL AT 9 O'CLOCK AT MH0 ft. MGO - General Observation - SERVICE LATERAL AT 3 O' CLOCK AT MH0 ft. MWL - Water Level, 35 %of cross sectional area3.7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES8.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start83.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"86.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"94.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish97.8 ft. AMH - Downstream Manhole, Survey Ends - 02 0225

Observations (11)

DistanceCodeObservation
94.6CM
83.3TF
0MWM
97.8AMH02 0225
0AMH02 0226
0MGOSERVICE LATERAL AT 9 O'CLOCK AT MH
8.1CM
0MGOSERVICE LATERAL AT 3 O' CLOCK AT MH
3.7CM
86.5TF
0MWL

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2015-09-15T22:31:04-07:00
documentation
PROPIPE
is_lateral_inspection
false