Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 16, 2015, 09:32 AM
  • 02 0216_02 0215A_16092015_024105.mp4

Date
09/16/2015
W/O
521010
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00251
PipeID
P02522
Time
2:32 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K2746
Sewer Name
02 DOWNEY-BELLFLOWER TRUNK
City
DOWNEY
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
27
Purpose
Routine Assessment
Project
WO_521010_TV02055_AUG2015
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
02 0216
Downstream MH
02 0215A
Dir. of Survey
Downstream
Length Surveyed
28.1 ft.
Total Length
28.1 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
5
Pipe schematic from manhole 02 0216 to 02 0215A
MH: 02 0216MH: 02 0215Adownstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 02160 ft. MGO - General Observation - SERVICE LATERAL AT 9 O'CLOCK AT MH0 ft. MWM - Water Mark, 25 %of cross sectional area6.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"8.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"14.4 ft. CM - Crack Multiple, from 12 to 04 o'clock, within 8 inches of joint: YES14.8 ft. DSZ - Deposits Settled Other, 5 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: NO28.1 ft. MGO - General Observation - SERVICE LATERAL AT 9 O'CLOCK AT MH28.1 ft. AMH - Downstream Manhole, Survey Ends - 02 0215A28.1 ft. MGO - General Observation - SERVICE LATERAL AT 3 O' CLOCK AT MH

Observations (11)

DistanceCodeObservation
14.4CM
0MWL
6.9TFC
0AMH02 0216
28.1MGOSERVICE LATERAL AT 9 O'CLOCK AT MH
28.1AMH02 0215A
8.9TF
14.8DSZ
28.1MGOSERVICE LATERAL AT 3 O' CLOCK AT MH
0MGOSERVICE LATERAL AT 9 O'CLOCK AT MH
0MWM

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2015-09-16T02:32:21-07:00
documentation
PROPIPE
is_lateral_inspection
false