Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 16, 2015, 07:13 AM
  • 02 0220_02 0219_16092015_004342.mp4

Date
09/16/2015
W/O
521010
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00251
PipeID
P02526
Time
12:13 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K2746
Sewer Name
02 DOWNEY-BELLFLOWER TRUNK
City
DOWNEY
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
27
Purpose
Routine Assessment
Project
WO_521010_TV02055_AUG2015
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
02 0220
Downstream MH
02 0219
Dir. of Survey
Downstream
Length Surveyed
375.5 ft.
Total Length
375.5 ft.
Structural Index
3
Structural Quick
3322
Structural Rating
13
O&M Index
1
O&M Quick
1100
O&M Rating
1
Overall Index
2
Overall Quick
Overall Rating
14
Pipe schematic from manhole 02 0220 to 02 0219
MH: 02 0220MH: 02 0219downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 02200 ft. MGO - General Observation - ABANDONED MH11.4 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES16.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"20 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"22.2 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES25.3 ft. CM - Crack Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES29.6 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start88.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"92.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"95.3 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"200.9 ft. CM - Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: NO209.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"212.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"309.2 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"309.2 ft. RFL - Roots Fine Lateral, at 10 o'clock312.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"375.5 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish375.5 ft. AMH - Downstream Manhole, Survey Ends - 02 0219

Observations (21)

DistanceCodeObservation
88.5TF
200.9CM
375.5CM
0MWL
375.5AMH02 0219
0MWM
309.2TFA
0AMH02 0220
16.5TFC
11.4CL
312.2TFC
212.1TFC
95.3TF
22.2CL
29.6CM
209.2TF
92.3TFC
0MGOABANDONED MH
309.2RFL
25.3CM
20TFC

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2015-09-16T00:13:08-07:00
documentation
PROPIPE
is_lateral_inspection
false