Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 15, 2015, 10:07 AM
  • 02 0234_02 0233_15092015_031453.mp4

Date
09/15/2015
W/O
521010
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00251
PipeID
P02542
Time
3:07 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K2745
Sewer Name
02 DOWNEY-BELLFLOWER TRUNK
City
DOWNEY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
27
Purpose
Routine Assessment
Project
WO_521010_TV02055_AUG2015
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
02 0233
Downstream MH
02 0234
Dir. of Survey
Upstream
Length Surveyed
135.4 ft.
Total Length
135.4 ft.
Structural Index
2
Structural Quick
3221
Structural Rating
9
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
11
Pipe schematic from manhole 02 0233 to 02 0234
MH: 02 0233MH: 02 0234upstream0 ft. AMH - Upstream Manhole, Survey Ends - 02 02340.6 ft. MGO - General Observation - SERVICE LATERAL AT 9 O'CLOCK AT MH1.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Finish4.8 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"8.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"101.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"104.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"110.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start114 ft. CL - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES118.6 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES130.6 ft. CC - Crack Circumferential, from 01 to 05 o'clock, within 8 inches of joint: YES132.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Start135.4 ft. AMH - Downstream Manhole, Survey Begins - 02 0233135.4 ft. MWL - Water Level, 15 %of cross sectional area135.4 ft. MGO - General Observation - SERVICE LATERAL AT 3 O' CLOCK AT MH135.4 ft. MWM - Water Mark, 35 %of cross sectional area

Observations (17)

DistanceCodeObservation
0AMH02 0233
0MWL
2.7DAGS
16.8CM
133.5DAGS
21.4CL
31.3TFC
4.8CC
24.9CM
130.6CM
0MGOSERVICE LATERAL AT 3 O' CLOCK AT MH
34.3TF
129.4TF
126.6TFC
0MWM
134.8MGOSERVICE LATERAL AT 9 O'CLOCK AT MH
135.4AMH02 0234

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2015-09-15T03:07:18-07:00
documentation
PROPIPE
is_lateral_inspection
false