Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 16, 2015, 08:15 AM
  • 02 0218_02 0217_16092015_012350.mp4

Date
09/16/2015
W/O
521010
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00251
PipeID
P02524
Time
1:15 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K2746
Sewer Name
02 DOWNEY-BELLFLOWER TRUNK
City
DOWNEY
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
27
Purpose
Routine Assessment
Project
WO_521010_TV02055_AUG2015
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
02 0218
Downstream MH
02 0217
Dir. of Survey
Downstream
Length Surveyed
196.6 ft.
Total Length
196.6 ft.
Structural Index
3
Structural Quick
3221
Structural Rating
8
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
8
Pipe schematic from manhole 02 0218 to 02 0217
MH: 02 0218MH: 02 0217downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 02180 ft. MGO - General Observation - SERVICE LATERAL AT 3 O' CLOCK AT MH0 ft. MWM - Water Mark, 30 %of cross sectional area2.2 ft. CM - Crack Multiple, from 01 to 04 o'clock, within 8 inches of joint: YES6.4 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES18.2 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start50 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"53 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"149.8 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"153 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"192.1 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish196.6 ft. AMH - Downstream Manhole, Survey Ends - 02 0217

Observations (13)

DistanceCodeObservation
192.1CM
0MWL
2.2CM
0AMH02 0218
50TF
0MGOSERVICE LATERAL AT 3 O' CLOCK AT MH
196.6AMH02 0217
0MWM
6.4CL
153TF
149.8TFA
53TF
18.2CM

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2015-09-16T01:15:06-07:00
documentation
PROPIPE
is_lateral_inspection
false