Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 15, 2015, 11:14 AM
  • 02 0229_02 0228_15092015_042941.mp4

Date
09/15/2015
W/O
521010
Weather
Light Rain
Operator/Surveyor
B.FUGATE
Sewer ID
Z00251
PipeID
P02535
Time
4:14 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K2745
Sewer Name
02 DOWNEY-BELLFLOWER TRUNK
City
DOWNEY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
27
Purpose
Routine Assessment
Project
WO_521010_TV02055_AUG2015
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
02 0229
Downstream MH
02 0228
Dir. of Survey
Downstream
Length Surveyed
378.1 ft.
Total Length
378.1 ft.
Structural Index
3
Structural Quick
3221
Structural Rating
8
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
8
Pipe schematic from manhole 02 0229 to 02 0228
MH: 02 0229MH: 02 0228downstream0 ft. MGO - General Observation - SERVICE LATERAL AT 3 O' CLOCK AT MH0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 02290 ft. MWL - Water Level, 15 %of cross sectional area30 ft. CM - Crack Multiple, from 11 to 03 o'clock, within 8 inches of joint: YES35 ft. CL - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES38.1 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start67.5 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"106.6 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"113.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"218.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"221.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"270.6 ft. TBA - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"318.1 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"321.2 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"357.4 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"374.4 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish378.1 ft. MGO - General Observation - SERVICE LATERAL AT 9 O'CLOCK AT MH378.1 ft. AMH - Downstream Manhole, Survey Ends - 02 0228

Observations (19)

DistanceCodeObservation
221.7TF
67.5TB
318.1TFA
270.6TBA
0MGOSERVICE LATERAL AT 3 O' CLOCK AT MH
218.5TFC
35CL
378.1MGOSERVICE LATERAL AT 9 O'CLOCK AT MH
374.4CM
0MWM
0AMH02 0229
38.1CM
378.1AMH02 0228
106.6TFA
0MWL
30CM
113.5TF
321.2TFA
357.4TB

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2015-09-15T04:14:30-07:00
documentation
PROPIPE
is_lateral_inspection
false