Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 16, 2015, 08:35 AM
  • 02 0222_02 0221_16092015_015248.mp4

Date
09/16/2015
W/O
521010
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00251
PipeID
P02528
Time
1:35 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K2746
Sewer Name
02 DOWNEY-BELLFLOWER TRUNK
City
DOWNEY
Loc. details
Sidewalk
Location Code
F
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
27
Purpose
Routine Assessment
Project
WO_521010_TV02055_AUG2015
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
02 0221
Downstream MH
02 0222
Dir. of Survey
Upstream
Length Surveyed
292.7 ft.
Total Length
292.7 ft.
Structural Index
3
Structural Quick
3525
Structural Rating
25
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
25
Pipe schematic from manhole 02 0221 to 02 0222
MH: 02 0221MH: 02 0222upstream0 ft. MGO - General Observation - SERVICE LATERAL AT 9 O'CLOCK AT MH0 ft. AMH - Upstream Manhole, Survey Ends - 02 02220 ft. MGO - General Observation - SERVICE LATERAL AT 3 O' CLOCK AT MH36.4 ft. CM - Crack Multiple, from 12 to 02 o'clock, within 8 inches of joint: YES44.9 ft. CM - Crack Multiple, from 09 to 01 o'clock, within 8 inches of joint: YES52.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"55.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"71 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES98.5 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES102.5 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES144.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"147.9 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"175.4 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES199.7 ft. CM - Crack Multiple, from 09 to 12 o'clock, within 8 inches of joint: YES208.5 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"220 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES235.6 ft. CL - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES239.8 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES265.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"268.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"292.7 ft. MWL - Water Level, 15 %of cross sectional area292.7 ft. MGO - General Observation - SERVICE LATERAL AT 9 O'CLOCK AT MH292.7 ft. AMH - Downstream Manhole, Survey Begins - 02 0221292.7 ft. MWM - Water Mark, 35 %of cross sectional area292.7 ft. MGO - General Observation - SERVICE LATERAL AT 3 O' CLOCK AT MH

Observations (25)

DistanceCodeObservation
292.7MGOSERVICE LATERAL AT 9 O'CLOCK AT MH
0MWL
194.2CL
27.4TFC
24.4TFC
144.8TFA
0MGOSERVICE LATERAL AT 9 O'CLOCK AT MH
84.2TB
0AMH02 0221
292.7AMH02 0222
292.7MGOSERVICE LATERAL AT 3 O' CLOCK AT MH
0MWM
256.3CM
237.4TF
221.7CM
117.3CM
0MGOSERVICE LATERAL AT 3 O' CLOCK AT MH
240.4TFC
247.8CM
57.1CL
93CM
148.2TFC
72.7CL
190.2CL
52.9CL

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2015-09-16T01:35:37-07:00
documentation
PROPIPE
is_lateral_inspection
false