Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 11, 2015, 10:05 AM
  • 02 0245_02 0244_11092015_032312.mp4

Date
09/11/2015
W/O
521010
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00251
PipeID
P02553
Time
3:05 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K2743
Sewer Name
02 DOWNEY-BELLFLOWER TRUNK
City
PICO RIVERA
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
25
Purpose
Routine Assessment
Project
WO_521010_TV02055_AUG2015
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
02 0245
Downstream MH
02 0244
Dir. of Survey
Downstream
Length Surveyed
482.8 ft.
Total Length
482.8 ft.
Structural Index
2
Structural Quick
3321
Structural Rating
14
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
16
Pipe schematic from manhole 02 0245 to 02 0244
MH: 02 0245MH: 02 0244downstream0 ft. AMH - Upstream Manhole, Survey Begins - 02 02450 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area3.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Start5.3 ft. CM - Crack Multiple, from 10 to 04 o'clock, within 8 inches of joint: YES35.7 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"86.4 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES140.2 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"232.5 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"269.7 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES306.9 ft. CC - Crack Circumferential, from 03 to 05 o'clock, within 8 inches of joint: YES308.1 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"322 ft. CM - Crack Multiple, from 02 to 04 o'clock, within 8 inches of joint: YES412 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"421.4 ft. JOM - Joint Offset Medium470.6 ft. JOM - Joint Offset Medium482.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Finish482.8 ft. AMH - Downstream Manhole, Survey Ends - 02 0244

Observations (18)

DistanceCodeObservation
482.7DAGS
232.5TFC
412TFC
0AMH02 0245
0MWL
322CM
306.9CC
470.6JOM
269.7CM
140.2TFC
482.8AMH02 0244
86.4CL
3.7DAGS
308.1TFC
35.7TFC
0MWM
421.4JOM
5.3CM

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2015-09-11T03:05:20-07:00
documentation
PROPIPE
is_lateral_inspection
false