Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 14, 2015, 10:10 AM
  • 02 0238_02 0237_14092015_032706.mp4

Date
09/14/2015
W/O
521010
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00251
PipeID
P02546
Time
3:10 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K2744
Sewer Name
02 DOWNEY-BELLFLOWER TRUNK
City
DOWNEY
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
28
Purpose
Routine Assessment
Project
WO_521010_TV02055_AUG2015
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
02 0238
Downstream MH
02 0237
Dir. of Survey
Downstream
Length Surveyed
403.2 ft.
Total Length
403.2 ft.
Structural Index
3
Structural Quick
3300
Structural Rating
9
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
11
Pipe schematic from manhole 02 0238 to 02 0237
MH: 02 0238MH: 02 0237downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 02380 ft. MWM - Water Mark, 35 %of cross sectional area2.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Start5.1 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES25.7 ft. CM - Crack Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES27.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start136.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"139.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"234.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"237.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"332.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"335.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"398.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish403.2 ft. AMH - Downstream Manhole, Survey Ends - 02 0237403.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Finish

Observations (16)

DistanceCodeObservation
403.2AMH02 0237
136.5TFC
2.7DAGS
403.2DAGS
25.7CM
234.5TFC
332.8TFC
5.1CM
0MWL
237.4TFC
139.2TFC
0AMH02 0238
335.6TFC
398.3CM
0MWM
27.9CM

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2015-09-14T03:10:25-07:00
documentation
PROPIPE
is_lateral_inspection
false