- Date
- 09/18/2015
- W/O
- 521010
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00251
- PipeID
- P02511
- Time
- 12:02 AM
- Certificate
- U-508-7069
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K2748
- Sewer Name
- 02 DOWNEY-BELLFLOWER TRUNK
- City
- DOWNEY
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 30
- Purpose
- Routine Assessment
- Project
- WO_521010_TV02055_AUG2015
- Sewer Type
- GRAVITY
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 21 in.
- Upstream MH
- 02 0203
- Downstream MH
- 02 0202
- Dir. of Survey
- Downstream
- Length Surveyed
- 388.6 ft.
- Total Length
- 388.6 ft.
- Structural Index
- 2
- Structural Quick
- 3211
- Structural Rating
- 7
- O&M Index
- 3
- O&M Quick
- 4122
- O&M Rating
- 8
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 15
Pipe schematic from manhole 02 0203 to 02 0202