Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 11, 2015, 09:09 AM
  • 02 0245A_02 0245_11092015_030447.mp4

Date
09/11/2015
W/O
521010
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00251
PipeID
P02554
Time
2:09 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K2743
Sewer Name
02 DOWNEY-BELLFLOWER TRUNK
City
PICO RIVERA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
25
Purpose
Routine Assessment
Project
WO_521010_TV02055_AUG2015
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
02 0245A
Downstream MH
02 0245
Dir. of Survey
Downstream
Length Surveyed
389.7 ft.
Total Length
389.7 ft.
Structural Index
3
Structural Quick
3321
Structural Rating
11
O&M Index
2
O&M Quick
3122
O&M Rating
8
Overall Index
2
Overall Quick
Overall Rating
19
Pipe schematic from manhole 02 0245A to 02 0245
MH: 02 0245AMH: 02 0245downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 0245A2.1 ft. DSZ - Deposits Settled Other, 15 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start3.3 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES11.6 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"100.9 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"101.5 ft. DSZ - Deposits Settled Other, 15 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish136.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Start160 ft. DSZ - Deposits Settled Other, 5 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: NO, Start220.3 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"221.6 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR333.2 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"363 ft. CM - Crack Multiple, from 08 to 09 o'clock, within 8 inches of joint: YES367.5 ft. CM - Crack Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES382.6 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES389.7 ft. AMH - Downstream Manhole, Survey Ends - 02 0245389.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Finish389.7 ft. DSZ - Deposits Settled Other, 5 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: NO, Finish

Observations (19)

DistanceCodeObservation
333.2TFC
220.3TFA
0MWL
389.7AMH02 0245
221.6RFJ
101.5DSZ
160DSZ
136.2DAGS
363CM
382.6CM
11.6TFC
389.7DAGS
100.9TF
3.3CL
0MWM
367.5CM
2.1DSZ
389.7DSZ
0AMH02 0245A

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2015-09-11T02:09:36-07:00
documentation
PROPIPE
is_lateral_inspection
false