Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 24, 2015, 07:39 AM
  • 02 0179_02 0178_24092015_005112.mp4

Date
09/24/2015
W/O
521010
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00251
PipeID
P02486
Time
12:39 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K2751
Sewer Name
02 DOWNEY-BELLFLOWER TRUNK
City
DOWNEY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
32
Purpose
Routine Assessment
Project
WO_521010_TV02055_AUG2015
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Upstream MH
02 0179
Downstream MH
02 0178
Dir. of Survey
Downstream
Length Surveyed
251.6 ft.
Total Length
251.6 ft.
Structural Index
2
Structural Quick
2200
Structural Rating
4
O&M Index
2
O&M Quick
2200
O&M Rating
4
Overall Index
2
Overall Quick
Overall Rating
8
Pipe schematic from manhole 02 0179 to 02 0178
MH: 02 0179MH: 02 0178downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 01790 ft. MWM - Water Mark, 30 %of cross sectional area8.2 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES16 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"18.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"64.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"67.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"110.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"113.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"118.8 ft. DSZ - Deposits Settled Other, 5 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: NO124 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES186.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"191.7 ft. DSZ - Deposits Settled Other, 5 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Start213.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"251.6 ft. DSZ - Deposits Settled Other, 5 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Finish251.6 ft. MGO - General Observation - SERVICE LATERAL AT 9 O'CLOCK AT MH251.6 ft. AMH - Downstream Manhole, Survey Ends - 02 0178

Observations (18)

DistanceCodeObservation
213.9TFC
118.8DSZ
67.6TF
0MWL
0AMH02 0179
124CL
64.6TFC
251.6DSZ
251.6MGOSERVICE LATERAL AT 9 O'CLOCK AT MH
113.3TF
0MWM
18.3TF
191.7DSZ
251.6AMH02 0178
8.2CL
186.3TF
110.7TFC
16TFC

Properties (5)

custom_field_two
4
customer
LACSD
datetime
2015-09-24T00:39:37-07:00
documentation
PROPIPE
is_lateral_inspection
false