Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 23, 2015, 06:49 AM
  • 02 0192A_02 0192_23092015_000000.mp4

Date
09/22/2015
W/O
521010
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00251
PipeID
P02501
Time
11:49 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K2750
Sewer Name
02 DOWNEY-BELLFLOWER TRUNK
City
DOWNEY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
30
Purpose
Routine Assessment
Project
WO_521010_TV02055_AUG2015
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Upstream MH
02 0192A
Downstream MH
02 0192
Dir. of Survey
Downstream
Length Surveyed
230.2 ft.
Total Length
230.2 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole 02 0192A to 02 0192
MH: 02 0192AMH: 02 0192downstream0 ft. AMH - Upstream Manhole, Survey Begins - 02 0192A0 ft. MGO - General Observation - SERVICE LATERAL AT 9 O'CLOCK AT MH0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area36.3 ft. CM - Crack Multiple, from 09 to 11 o'clock, within 8 inches of joint: YES46.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"50.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"86.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"90 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"154.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"158.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"164.5 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"198.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"201.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"230.2 ft. AMH - Downstream Manhole, Survey Ends - 02 0192

Observations (15)

DistanceCodeObservation
198.5TF
158.1TFC
201.4TFC
86.9TF
0AMH02 0192A
154.5TFC
46.7TF
50.1TFC
0MGOSERVICE LATERAL AT 9 O'CLOCK AT MH
0MWM
0MWL
164.5TBA
90TFC
36.3CM
230.2AMH02 0192

Properties (5)

custom_field_two
4
customer
LACSD
datetime
2015-09-22T23:49:40-07:00
documentation
PROPIPE
is_lateral_inspection
false