Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 10, 2015, 09:20 AM
  • 02 0257_02 0256_10092015_023313.mp4

Date
09/10/2015
W/O
521010
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00251
PipeID
P02566
Time
2:20 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K2740
Sewer Name
02 DOWNEY-BELLFLOWER TRUNK
City
PICO RIVERA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
25
Purpose
Routine Assessment
Project
WO_521010_TV02055_AUG2015
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
02 0257
Downstream MH
02 0256
Dir. of Survey
Downstream
Length Surveyed
393.5 ft.
Total Length
393.5 ft.
Structural Index
3
Structural Quick
3221
Structural Rating
8
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
8
Pipe schematic from manhole 02 0257 to 02 0256
MH: 02 0257MH: 02 0256downstream0 ft. AMH - Upstream Manhole, Survey Begins - 02 02570 ft. MWM - Water Mark, 5 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area6.2 ft. CM - Crack Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES10.5 ft. CL - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES18.3 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start31.8 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"120.2 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"224.8 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"324.6 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"387.8 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish393.5 ft. AMH - Downstream Manhole, Survey Ends - 02 0256

Observations (12)

DistanceCodeObservation
120.2TF
10.5CL
0AMH02 0257
393.5AMH02 0256
18.3CM
31.8TF
0MWM
324.6TF
6.2CM
0MWL
387.8CM
224.8TF

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2015-09-10T02:20:41-07:00
documentation
PROPIPE
is_lateral_inspection
false