Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 21, 2018, 10:35 AM
  • 32 0152_32 0151_21082018_034512.mp4

Date
08/21/2018
W/O
723911
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00887
PipeID
P19903
Time
3:35 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6007
Sewer Name
32 DISTRICT #32 MAIN TRUNK
City
SANTA CLARITA
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
13
Purpose
Routine Assessment
Project
WO_723911_TV32048_SEP2018
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
32 0151
Downstream MH
32 0152
Dir. of Survey
Upstream
Length Surveyed
152.2 ft.
Total Length
152.2 ft.
Structural Index
3
Structural Quick
3E00
Structural Rating
90
O&M Index
2
O&M Quick
2E00
O&M Rating
60
Overall Index
3
Overall Quick
Overall Rating
150
Pipe schematic from manhole 32 0151 to 32 0152
MH: 32 0151MH: 32 0152upstream0 ft. AMH - Upstream Manhole, Survey Ends - 32 01520 ft. MGO - General Observation - COCKROACHES IN MANHOLE2.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish2.3 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish143 ft. MGO - General Observation - MAG COATING THROUGHOUT 50%150.2 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start150.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start152.2 ft. AMH - Downstream Manhole, Survey Begins - 32 0151152.2 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 2 O'CLOCK152.2 ft. MWM - Water Mark, 40 %of cross sectional area152.2 ft. MWL - Water Level, 10 %of cross sectional area

Observation photos (3)

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MANHOLE

    152.2 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (11)

DistanceCodeObservation
152.2AMH32 0152
152.2MGOCOCKROACHES IN MANHOLE
0AMH32 0151
2SAP
149.9DAGS
0MGOACTIVE CONNECTION AT MH 2 O'CLOCK
0MWM
0MWL
2DAGS
9.2MGOMAG COATING THROUGHOUT 50%
149.9SAP

Properties (6)

additional_info
SC364777
custom_field_two
2
customer
LACSD
datetime
2018-08-21T03:35:40-07:00
documentation
PRO PIPE
is_lateral_inspection
false