Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 24, 2018, 05:36 AM
  • 32 0138_32 0137A _23082018_225024.mp4

Date
08/23/2018
W/O
723911
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00887
PipeID
P19886
Time
10:36 PM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6016
Sewer Name
32 DISTRICT #32 MAIN TRUNK
City
SANTA CLARITA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
09
Purpose
Routine Assessment
Project
WO_723911_TV32048_SEP2018
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
32 0138
Downstream MH
32 0137A
Dir. of Survey
Downstream
Length Surveyed
246.8 ft.
Total Length
246.8 ft.
Structural Index
3
Structural Quick
3200
Structural Rating
6
O&M Index
2
O&M Quick
2200
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
10
Pipe schematic from manhole 32 0138 to 32 0137A
MH: 32 0138MH: 32 0137Adownstream0 ft. AMH - Upstream Manhole, Survey Begins - 32 01380 ft. MWL - Water Level, 25 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start244.2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish244.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish246.8 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 9 O'CLOCK246.8 ft. MGO - General Observation - COCKROACHES IN MANHOLE246.8 ft. AMH - Downstream Manhole, Survey Ends - 32 0137A

Observation photos (3)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MANHOLE

    246.8 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (10)

DistanceCodeObservation
244.2SAP
2DAGS
2SAP
0AMH32 0138
246.8MGOACTIVE CONNECTION AT MH 9 O'CLOCK
0MWL
246.8MGOCOCKROACHES IN MANHOLE
0MWM
246.8AMH32 0137A
244.2DAGS

Properties (6)

additional_info
SC364780
custom_field_two
2
customer
LACSD
datetime
2018-08-23T22:36:49-07:00
documentation
PRO PIPE
is_lateral_inspection
false