Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 22, 2018, 07:25 AM
  • 32 0131_32 0130_22082018_005306.mp4

Date
08/22/2018
W/O
723911
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00887
PipeID
P19877
Time
12:25 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6008
Sewer Name
32 DISTRICT #32 MAIN TRUNK
City
SANTA CLARITA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
08
Purpose
Routine Assessment
Project
WO_723911_TV32048_SEP2018
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
32 0131
Downstream MH
32 0130
Dir. of Survey
Downstream
Length Surveyed
475.5 ft.
Total Length
475.5 ft.
Structural Index
3
Structural Quick
3R2R
Structural Rating
470
O&M Index
2
O&M Quick
412R
O&M Rating
192
Overall Index
2
Overall Quick
Overall Rating
662
Pipe schematic from manhole 32 0131 to 32 0130
MH: 32 0131MH: 32 0130downstream0 ft. AMH - Upstream Manhole, Survey Begins - 32 01310 ft. MWL - Water Level, 30 %of cross sectional area0 ft. MWM - Water Mark, 50 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start2 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start473.8 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish473.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish473.8 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish475.5 ft. MGO - General Observation - COCKROACHES IN MANHOLE475.5 ft. AMH - Downstream Manhole, Survey Ends - 32 0130

Observation photos (4)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MANHOLE

    475.5 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (11)

DistanceCodeObservation
2DAGS
473.8SSS
475.5MGOCOCKROACHES IN MANHOLE
2SSS
0AMH32 0131
0MWL
0MWM
2SAP
475.5AMH32 0130
473.8DAGS
473.8SAP

Properties (6)

additional_info
SC364778
custom_field_two
2
customer
LACSD
datetime
2018-08-22T00:25:47-07:00
documentation
PRO PIPE
is_lateral_inspection
false