Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 13, 2019, 04:51 PM
  • 05 0473_05 0472_8132019_095342.mp4

Date
08/13/2019
W/O
0786503
Weather
Dry
Operator/Surveyor
FRANKLIN
Sewer ID
Z00526
PipeID
P05688
Time
9:51 AM
Certificate
U-415-06024039
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G8053
Sewer Name
05 STRAWBERRY AVENUE TRUNK
City
HAWTHORNE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
13
Purpose
Routine Assessment
Project
20190812DF_STRAWBERRY_AVENUE_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Upstream MH
05 0472
Downstream MH
05 0473
Dir. of Survey
Upstream
Length Surveyed
299.5 ft.
Total Length
299.5 ft.
Structural Index
3
Structural Quick
3121
Structural Rating
5
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
5
Pipe schematic from manhole 05 0472 to 05 0473
MH: 05 0472MH: 05 0473upstream0 ft. MGO - General Observation - Mag Coat xx% 9 to 3 o' Clock Throughout0 ft. AMH - Upstream Manhole, Survey Ends - 10:19 AM0 ft. MGO - General Observation - ROACHES @ MH1.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish1.9 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish7.1 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"55.5 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"57.8 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"106.3 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"108.8 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"157.4 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"160.1 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"206.1 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"213.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4" - Open259.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4" - Open262 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"297.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start297.5 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start299.5 ft. AMH - Downstream Manhole, Survey Begins - 9:52 AM299.5 ft. MWM - Water Mark, 15 %of cross sectional area299.5 ft. MWL - Water Level, 10 %of cross sectional area299.5 ft. MGO - General Observation - ROACHES @ MH

Observation photos (3)

  • Downstream Manhole, Survey Begins - 9:52 AM

    0 ft. - Downstream Manhole, Survey Begins - 9:52 AM

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (22)

DistanceCodeObservation
241.7TFA
0AMH9:52 AM
40TFOpen
2CM
299.5MGOMag Coat xx% 9 to 3 o' Clock Throughout
190.7TFA
93.4TFA
292.4TFA
0MWM
142.1TFA
299.5AMH10:19 AM
0MWL
297.6CM
37.5TFA
0MGOROACHES @ MH
244TFA
299.5MGOROACHES @ MH
139.4TFA
193.2TFA
2SSS
297.6SSS
86TFOpen

Properties (6)

additional_info
ON SCREEN PIPE ID IS WRONG. CORRECT NUMBER IS (P05688)
custom_field_two
3
customer
LACSD
datetime
2019-08-13T09:51:02-07:00
documentation
FRANKLIN, CASTILLO, RUVALCABA
is_lateral_inspection
false