- Date
- 08/15/2019
- W/O
- 0784628
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00032
- PipeID
- P23530
- Time
- 2:06 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- I0216
- Sewer Name
- E JOINT OUTFALL E - UNIT 5
- City
- WILLOWBROOK
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 01
- Page No.
- 13
- Purpose
- Routine Assessment
- Project
- 20190813MDM_JOINT_OUTFALL_E_UNIT_5
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 36 in.
- Upstream MH
- E 0107
- Downstream MH
- E 0158
- Dir. of Survey
- Downstream
- Length Surveyed
- 37.5 ft.
- Total Length
- 37.5 ft.
- Structural Index
- 2
- Structural Quick
- 2B00
- Structural Rating
- 30
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 30
Pipe schematic from manhole E 0107 to E 0158 Observation photos (5)

2 ft. - General Observation - MAG COAT 98% START

2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE UNDER MAG COAT

8 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELIN CONCRETE

14.1 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING CONCRETE

24 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING PEELING CONCRETE