- Date
- 01/09/2019
- W/O
- 740340
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00040
- PipeID
- P10225
- Time
- 1:17 AM
- Certificate
- U-508-7069
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K6319
- Sewer Name
- F JOINT OUTFALL F - UNIT 4 RELIEF
- City
- NORWALK
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 33
- Purpose
- Routine Assessment
- Project
- RFIR_WO_740340_TV02367_DEC2018
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 39 in.
- Width
- 39 in.
- Upstream MH
- F 0272
- Downstream MH
- F 0271
- Dir. of Survey
- Downstream
- Length Surveyed
- 256.3 ft.
- Total Length
- 256.3 ft.
- Structural Index
- 3
- Structural Quick
- 513I
- Structural Rating
- 155
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 155
Pipe schematic from manhole F 0272 to F 0271 Observation photos (2)

6.2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

223.7 ft. - Surface Reinforcement Visible, from 03 to 04 o'clock, within 8 inches of joint: NO