Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 16, 2019, 05:46 PM
  • 05 0522_05 0521_8162019_104840.mp4

Date
08/16/2019
W/O
0787369
Weather
Dry
Operator/Surveyor
FRANKLIN
Sewer ID
Z00459
PipeID
P05740
Time
10:46 AM
Certificate
U-415-06024039
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Jetting
Media Label
G8057
Sewer Name
05 INGLEWOOD TRUNK #1
City
INGLEWOOD
Loc. details
Other
Location Code
Z
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
05
Purpose
Maintenance Related
Project
20190816DF_INGLEWOOD_TRUNK_1
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Upstream MH
05 0521
Downstream MH
05 0522
Dir. of Survey
Upstream
Length Surveyed
353.5 ft.
Total Length
353.5 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole 05 0521 to 05 0522
MH: 05 0521MH: 05 0522upstream0 ft. AMH - Upstream Manhole, Survey Ends - 11:14 AM0 ft. MGO - General Observation - Grease Throughout The Reach (5%)2 ft. MGP - General Photograph77.4 ft. MGP - General Photograph182.6 ft. MGP - General Photograph204.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4" - Open237.8 ft. MGP - General Photograph266.8 ft. TB - Tap Break-In, at 01 o'clock, -, within 8 inches of joint: YES, 4" - Open285.1 ft. LFW - Lining Failure Wrinkled, at 05 o'clock, within 8 inches of joint: YES, Finish293.5 ft. LFW - Lining Failure Wrinkled, at 05 o'clock, within 8 inches of joint: YES, Start329.2 ft. MGP - General Photograph353.5 ft. AMH - Downstream Manhole, Survey Begins - 10:47 AM353.5 ft. MWM - Water Mark, 10 %of cross sectional area353.5 ft. MWL - Water Level, 5 %of cross sectional area

Observation photos (8)

  • Downstream Manhole, Survey Begins - 10:47 AM

    0 ft. - Downstream Manhole, Survey Begins - 10:47 AM

  • General Photograph

    24.3 ft. - General Photograph

  • Lining Failure Wrinkled, at 05 o'clock, within 8 inches of joint: YES, Start

    60 ft. - Lining Failure Wrinkled, at 05 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In, at 01 o'clock, -, within 8 inches of joint: YES, 4" - Open

    86.7 ft. - Tap Break-In, at 01 o'clock, -, within 8 inches of joint: YES, 4" - Open

  • General Photograph

    115.7 ft. - General Photograph

  • General Photograph

    170.9 ft. - General Photograph

  • General Photograph

    276.1 ft. - General Photograph

  • General Photograph

    351.5 ft. - General Photograph

Observations (14)

DistanceCodeObservation
149.4TFOpen
60LFW
170.9MGP
68.4LFW
353.5AMH11:14 AM
276.1MGP
86.7TBOpen
24.3MGP
115.7MGP
0AMH10:47 AM
351.5MGP
0MWM
353.5MGOGrease Throughout The Reach (5%)
0MWL

Properties (5)

custom_field_two
4
customer
LACSD
datetime
2019-08-16T10:46:10-07:00
documentation
FRANKLIN, CASTILLO, RUVALCABA, IGNACIO
is_lateral_inspection
false