- Date
- 06/26/2019
- W/O
- 766659
- Weather
- Dry
- Operator/Surveyor
- J. VARGAS
- Sewer ID
- Z00168
- PipeID
- P10635
- Time
- 12:34 AM
- Certificate
- U-209-8149
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K5585
- Sewer Name
- H JOINT OUTFALL H - UNIT 2B
- City
- BELL GARDENS
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 23
- Purpose
- Routine Assessment
- Project
- WO_766659_TV02360_MAY2019
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 39 in.
- Width
- 39 in.
- Upstream MH
- H 0188
- Downstream MH
- H 0187
- Dir. of Survey
- Downstream
- Length Surveyed
- 473.2 ft.
- Total Length
- 473.2 ft.
- Structural Index
- 3
- Structural Quick
- 433R
- Structural Rating
- 473
- O&M Index
- 2
- O&M Quick
- 2R00
- O&M Rating
- 186
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 659
Pipe schematic from manhole H 0188 to H 0187 Observation photos (5)

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

12.6 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

67.2 ft. - Surface Aggregate Missing, from 10 to 02 o'clock, within 8 inches of joint: YES, Start

467.9 ft. - General Observation - MAG COAT THROUGHOUT PIPE