Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 12, 2019, 08:40 AM
  • 7_1_3_12042019_021424.mp4

Date
04/12/2019
W/O
761426
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00141
PipeID
P09840
Time
1:40 AM
Certificate
U-115-06022794
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K5927
Sewer Name
C JOINT OUTFALL C - UNIT 8C
City
LAKEWOOD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 19
Page No.
06
Purpose
Routine Assessment
Project
WO_761426_TV19012_APR2019
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
27 in.
Width
27 in.
Upstream MH
C 0377
Downstream MH
C 0376
Dir. of Survey
Downstream
Length Surveyed
643.4 ft.
Total Length
643.4 ft.
Structural Index
3
Structural Quick
513Y
Structural Rating
645
O&M Index
2
O&M Quick
5543
O&M Rating
311
Overall Index
2
Overall Quick
Overall Rating
956
Pipe schematic from manhole C 0377 to C 0376
MH: C 0377MH: C 0376downstream0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - C 03770 ft. MWL - Water Level, 20 %of cross sectional area3 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start3 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start3.1 ft. DAZ - Deposits Attached Other, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start - MAG COAT57.8 ft. IG - Infiltration Gusher, at 04 o'clock, within 8 inches of joint: YES65.7 ft. IR - Infiltration Runner, at 12 o'clock, within 8 inches of joint: YES83 ft. ID - Infiltration Dripper, at 12 o'clock, within 8 inches of joint: YES129.7 ft. ID - Infiltration Dripper, at 12 o'clock, within 8 inches of joint: YES219.2 ft. ID - Infiltration Dripper, at 12 o'clock, within 8 inches of joint: YES227.6 ft. IG - Infiltration Gusher, at 04 o'clock, within 8 inches of joint: YES274.5 ft. ID - Infiltration Dripper, at 11 o'clock, within 8 inches of joint: YES509.1 ft. SRV - Surface Reinforcement Visible, from 12 to 02 o'clock, within 8 inches of joint: NO534.4 ft. IG - Infiltration Gusher, at 04 o'clock, within 8 inches of joint: YES542 ft. ID - Infiltration Dripper, at 12 o'clock, within 8 inches of joint: YES615 ft. IG - Infiltration Gusher, at 04 o'clock, within 8 inches of joint: YES619.7 ft. LR - Alignment Right, 25 %629.4 ft. ID - Infiltration Dripper, at 04 o'clock, within 8 inches of joint: YES633.9 ft. IG - Infiltration Gusher, at 04 o'clock, within 8 inches of joint: YES641 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish641.7 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish641.7 ft. DAZ - Deposits Attached Other, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Finish641.9 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK643.4 ft. AMH - Downstream Manhole, Survey Ends - C 0376

Observation photos (16)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Other, 5 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: YES, Start - MAG COAT

    3.1 ft. - Deposits Attached Other, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start - MAG COAT

  • Infiltration Gusher, at 04 o'clock, within 8 inches of joint: YES

    57.8 ft. - Infiltration Gusher, at 04 o'clock, within 8 inches of joint: YES

  • Infiltration Runner, at 12 o'clock, within 8 inches of joint: YES

    65.7 ft. - Infiltration Runner, at 12 o'clock, within 8 inches of joint: YES

  • Infiltration Dripper, at 12 o'clock, within 8 inches of joint: YES

    83 ft. - Infiltration Dripper, at 12 o'clock, within 8 inches of joint: YES

  • Infiltration Dripper, at 12 o'clock, within 8 inches of joint: YES

    129.7 ft. - Infiltration Dripper, at 12 o'clock, within 8 inches of joint: YES

  • Infiltration Dripper, at 12 o'clock, within 8 inches of joint: YES

    219.2 ft. - Infiltration Dripper, at 12 o'clock, within 8 inches of joint: YES

  • Infiltration Gusher, at 04 o'clock, within 8 inches of joint: YES

    227.6 ft. - Infiltration Gusher, at 04 o'clock, within 8 inches of joint: YES

  • Infiltration Dripper, at 11 o'clock, within 8 inches of joint: YES

    274.5 ft. - Infiltration Dripper, at 11 o'clock, within 8 inches of joint: YES

  • Infiltration Gusher, at 04 o'clock, within 8 inches of joint: YES

    534.4 ft. - Infiltration Gusher, at 04 o'clock, within 8 inches of joint: YES

  • Infiltration Dripper, at 12 o'clock, within 8 inches of joint: YES

    542 ft. - Infiltration Dripper, at 12 o'clock, within 8 inches of joint: YES

  • Infiltration Gusher, at 04 o'clock, within 8 inches of joint: YES

    615 ft. - Infiltration Gusher, at 04 o'clock, within 8 inches of joint: YES

  • Alignment Right, 25 %

    619.7 ft. - Alignment Right, 25 %

  • Infiltration Dripper, at 04 o'clock, within 8 inches of joint: YES

    629.4 ft. - Infiltration Dripper, at 04 o'clock, within 8 inches of joint: YES

  • Infiltration Gusher, at 04 o'clock, within 8 inches of joint: YES

    633.9 ft. - Infiltration Gusher, at 04 o'clock, within 8 inches of joint: YES

  • General Observation - CONNECTION AT MH 3 O'CLOCK

    641.9 ft. - General Observation - CONNECTION AT MH 3 O'CLOCK

Observations (25)

DistanceCodeObservation
0MWM
3SAP
619.7LR
641.9MGOCONNECTION AT MH 3 O'CLOCK
0AMHC 0377
83ID
641.7SAP
643.4AMHC 0376
219.2ID
65.7IR
615IG
274.5ID
509.1SRV
633.9IG
57.8IG
641SSS
227.6IG
129.7ID
629.4ID
3.1DAZMAG COAT
641.7DAZ
3SSS
542ID
0MWL
534.4IG

Properties (6)

custom_field_two
2
customer
LACSD
datetime
2019-04-12T01:40:12-07:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
26760