Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 13, 2019, 07:08 AM
  • 14 0663_14 0662 _06132019_004431.mp4

Date
06/13/2019
W/O
671823
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00568
PipeID
P18752
Time
12:08 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6606
Sewer Name
14 AMARGOSA CREEK TRUNK
City
LANCASTER
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 14
Page No.
23
Purpose
Routine Assessment
Project
WO_671823_TV14005_MAY2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
14 0663
Downstream MH
14 0662
Dir. of Survey
Downstream
Length Surveyed
470.3 ft.
Total Length
470.3 ft.
Structural Index
3
Structural Quick
3R2R
Structural Rating
465
O&M Index
2
O&M Quick
2R00
O&M Rating
186
Overall Index
2
Overall Quick
Overall Rating
651
Pipe schematic from manhole 14 0663 to 14 0662
MH: 14 0663MH: 14 0662downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 14 06630 ft. MWM - Water Mark, 20 %of cross sectional area2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start467 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish468.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish469 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish470.3 ft. AMH - Downstream Manhole, Survey Ends - 14 0662

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

Observations (10)

DistanceCodeObservation
0MWL
470.3AMH14 0662
0AMH14 0663
2CM
469CM
0MWM
2DAGS
467SSS
2SSS
468.9DAGS

Properties (6)

additional_info
SC378172
customer
LACSD
datetime
2019-06-13T00:08:19-07:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
31748