Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 13, 2019, 09:10 AM
  • 14 0666_14 0665 _06132019_022430.mp4

Date
06/13/2019
W/O
671823
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00568
PipeID
P18755
Time
2:10 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6606
Sewer Name
14 AMARGOSA CREEK TRUNK
City
LANCASTER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 14
Page No.
23
Purpose
Routine Assessment
Project
WO_671823_TV14005_MAY2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
14 0666
Downstream MH
14 0665
Dir. of Survey
Downstream
Length Surveyed
402 ft.
Total Length
402 ft.
Structural Index
2
Structural Quick
2O00
Structural Rating
160
O&M Index
2
O&M Quick
2O00
O&M Rating
160
Overall Index
2
Overall Quick
Overall Rating
320
Pipe schematic from manhole 14 0666 to 14 0665
MH: 14 0666MH: 14 0665downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 14 06660 ft. MWM - Water Mark, 15 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start135.7 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"153.6 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"299.7 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN400 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish401.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish402 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK/OPEN402 ft. AMH - Downstream Manhole, Survey Ends - 14 0665

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

Observations (12)

DistanceCodeObservation
0MWL
0AMH14 0666
135.7TBA
402MGOCONNECTION AT MH 3 O'CLOCK/OPEN
299.7TBOPEN
0MWM
2DAGS
402AMH14 0665
400SSS
153.6TB
2SSS
401.3DAGS

Properties (7)

additional_info
SC378172
custom_field_two
4
customer
LACSD
datetime
2019-06-13T02:10:27-07:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
31748