Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 19, 2019, 10:18 AM
  • 15 0773_15 0772 _02192019_021933.mp4

Date
02/19/2019
W/O
750672
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00593
PipeID
P12974
Time
2:18 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6399
Sewer Name
15 ARCADIA-SIERRA MADRE TRUNK, SECTS 2&5
City
ARCADIA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
04
Purpose
Routine Assessment
Project
RFIR_WO_750672_TV15146_FEB2019
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
15 0773
Downstream MH
15 0772
Dir. of Survey
Downstream
Length Surveyed
401.1 ft.
Total Length
401.1 ft.
Structural Index
3
Structural Quick
3O00
Structural Rating
240
O&M Index
2
O&M Quick
2O00
O&M Rating
160
Overall Index
3
Overall Quick
Overall Rating
400
Pipe schematic from manhole 15 0773 to 15 0772
MH: 15 0773MH: 15 0772downstream0 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 3 O'CLOCK0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 15 07732 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start16.1 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"62.8 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES82.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"130.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"133.9 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"270 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"273.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"321.5 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"324.4 ft. RTL - Roots Tap Lateral, from 01 to 03 o'clock, 10 %, within 8 inches of joint: YES324.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"398.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish398.7 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish401.1 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 3 AND 9 O'CLOCK401.1 ft. AMH - Downstream Manhole, Survey Ends - 15 0772

Observation photos (4)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    62.8 ft. - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES

  • Roots Tap Lateral, from 01 to 03 o'clock, 10 %, within 8 inches of joint: YES

    324.4 ft. - Roots Tap Lateral, from 01 to 03 o'clock, 10 %, within 8 inches of joint: YES

Observations (20)

DistanceCodeObservation
0MGOACTIVE CONNECTION AT MH 3 O'CLOCK
398.7DAGS
270TFC
133.9TFA
0MWM
401.1MGOACTIVE CONNECTION AT MH 3 AND 9 O'CLOCK
324.4RTL
16.1TFA
273.2TFC
401.1AMH15 0772
0MWL
324.4TF
62.8FL
82.5TFC
321.5TFA
130.6TFC
2SAP
0AMH15 0773
2DAGS
398.7SAP

Properties (6)

additional_info
SC365911
custom_field_two
2
customer
LACSD
datetime
2019-02-19T02:18:52-08:00
documentation
PRO PIPE
is_lateral_inspection
false