Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 19, 2019, 11:16 AM
  • 15 0770_15 0769 _02192019_031630.mp4

Date
02/19/2019
W/O
750672
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00593
PipeID
P12971
Time
3:16 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6399
Sewer Name
15 ARCADIA-SIERRA MADRE TRUNK, SECTS 2&5
City
ARCADIA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
04
Purpose
Routine Assessment
Project
RFIR_WO_750672_TV15146_FEB2019
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
15 0770
Downstream MH
15 0769
Dir. of Survey
Downstream
Length Surveyed
397.4 ft.
Total Length
397.4 ft.
Structural Index
3
Structural Quick
3O2N
Structural Rating
391
O&M Index
2
O&M Quick
2O11
O&M Rating
159
Overall Index
2
Overall Quick
Overall Rating
550
Pipe schematic from manhole 15 0770 to 15 0769
MH: 15 0770MH: 15 0769downstream0 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 3 AND 9 O'CLOCK0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 15 07700 ft. MWL - Water Level, 20 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start2 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start9.4 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start107.4 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"110.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"139 ft. RFJ - Roots Fine Joint, from 08 to 10 o'clock, within 8 inches of joint: YESR160.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"162.2 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"187.2 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"280.5 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"336.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"366.4 ft. TBA - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"395.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish395.6 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish395.6 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish397.4 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 9 O'CLOCK397.4 ft. AMH - Downstream Manhole, Survey Ends - 15 0769

Observation photos (4)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    9.4 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Roots Fine Joint, from 08 to 10 o'clock, within 8 inches of joint: YESR

    139 ft. - Roots Fine Joint, from 08 to 10 o'clock, within 8 inches of joint: YESR

Observations (21)

DistanceCodeObservation
336.4TF
395.6DAGS
187.2TBA
2DAGS
9.4SSS
366.4TBA
395.6SAP
395.6SSS
110.5TF
107.4TFA
162.2TFA
0MGOACTIVE CONNECTION AT MH 3 AND 9 O'CLOCK
139RFJ
0MWM
2SAP
160.8TFC
397.4MGOACTIVE CONNECTION AT MH 9 O'CLOCK
397.4AMH15 0769
280.5TB
0AMH15 0770
0MWL

Properties (6)

additional_info
SC365911
custom_field_two
2
customer
LACSD
datetime
2019-02-19T03:16:14-08:00
documentation
PRO PIPE
is_lateral_inspection
false