Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 23, 2019, 09:06 AM
  • 15 0251_15 0250_07232019_024016.mp4

Date
07/23/2019
W/O
766400
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00627
PipeID
P12173
Time
2:06 AM
Certificate
U-115-0602794
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K5936
Sewer Name
15 SAN JOSE CREEK TRUNK
City
CITY OF INDUSTRY
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
34
Purpose
Routine Assessment
Project
WO_766400_TV15133_MAY2019
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
15 0251
Downstream MH
15 0250
Dir. of Survey
Downstream
Length Surveyed
11.5 ft.
Total Length
11.5 ft.
Structural Index
3
Structural Quick
3200
Structural Rating
6
O&M Index
5
O&M Quick
5200
O&M Rating
10
Overall Index
4
Overall Quick
Overall Rating
16
Pipe schematic from manhole 15 0251 to 15 0250
MH: 15 0251MH: 15 0250downstream0 ft. MWL - Water Level, 70 %of cross sectional area0 ft. MWM - Water Mark, 75 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 15 02512.1 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start2.1 ft. MGO - General Observation - MAG COAT9.3 ft. DAGS - Deposits Attached Grease, 35 %of cross sectional area, from 08 to 12 o'clock, , within 8 inches of joint: YES10 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 8"11.5 ft. MSA - Survey Abandoned - UNABLE TO GET PAST GREEASE11.5 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish

Observation photos (5)

  • Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • General Observation - MAG COAT

    2.1 ft. - General Observation - MAG COAT

  • Deposits Attached Grease, 35 %of cross sectional area, from 08 to 12 o'clock,  , within 8 inches of joint: YES

    9.3 ft. - Deposits Attached Grease, 35 %of cross sectional area, from 08 to 12 o'clock, , within 8 inches of joint: YES

  • Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 8"

    10 ft. - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 8"

  • Survey Abandoned - UNABLE TO GET PAST GREEASE

    11.5 ft. - Survey Abandoned - UNABLE TO GET PAST GREEASE

Observations (9)

DistanceCodeObservation
11.5MSAUNABLE TO GET PAST GREEASE
2.1SAV
0MWL
10TBA
0MWM
2.1MGOMAG COAT
0AMH15 0251
11.5SAV
9.3DAGS

Properties (5)

custom_field_two
5
customer
LACSD
datetime
2019-07-23T02:06:38-07:00
documentation
PROPIPE
is_lateral_inspection
false