Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 23, 2018, 11:10 AM
  • 18 0101_18 0100 _23072018_041927.mpg

Date
07/23/2018
W/O
716712
Weather
Dry
Operator/Surveyor
E.RUIZ
Sewer ID
Z00698
PipeID
P13921
Time
4:10 AM
Certificate
U-715-07000753
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K5320
Sewer Name
18 SANTA FE STREET TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
22
Purpose
Routine Assessment
Project
WO_716712_TV18177_JUL2018
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
18 0101
Downstream MH
18 0100
Dir. of Survey
Downstream
Length Surveyed
129.6 ft.
Total Length
129.6 ft.
Structural Index
3
Structural Quick
3D21
Structural Rating
77
O&M Index
1
O&M Quick
1100
O&M Rating
1
Overall Index
3
Overall Quick
Overall Rating
78
Pipe schematic from manhole 18 0101 to 18 0100
MH: 18 0101MH: 18 0100downstream0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - 18 01010 ft. MWM - Water Mark, 30 %of cross sectional area3 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start31.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"34 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"83.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"86.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"107.2 ft. RFJ - Roots Fine Joint, from 04 to 05 o'clock, within 8 inches of joint: YES122.9 ft. CL - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES127.8 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish129.6 ft. AMH - Downstream Manhole, Survey Ends - 18 0100

Observation photos (3)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Roots Fine Joint, from 04 to 05 o'clock, within 8 inches of joint: YES

    107.2 ft. - Roots Fine Joint, from 04 to 05 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

    122.9 ft. - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

Observations (14)

DistanceCodeObservation
0MGOCONNECTION AT MH 9 O'CLOCK
31.1TFC
0MWL
86.4TFC
34TFC
83.4TFC
122.9CL
107.2RFJ
0MGOCONNECTION AT MH 3 O'CLOCK
0AMH18 0101
129.6AMH18 0100
3SAP
127.8SAP
0MWM

Properties (5)

custom_field_two
2
customer
LACSD
datetime
2018-07-23T04:10:48-07:00
documentation
PROPIPE
is_lateral_inspection
false