Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 24, 2018, 06:32 AM
  • 18 0092_18 0091 _23072018_234731.mpg

Date
07/23/2018
W/O
716712
Weather
Dry
Operator/Surveyor
E.RUIZ
Sewer ID
Z00698
PipeID
P13911
Time
11:32 PM
Certificate
U-715-07000753
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K5321
Sewer Name
18 SANTA FE STREET TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
21
Purpose
Routine Assessment
Project
WO_716712_TV18177_JUL2018
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
18 0092
Downstream MH
18 0091
Dir. of Survey
Downstream
Length Surveyed
328.6 ft.
Total Length
328.6 ft.
Structural Index
3
Structural Quick
3L21
Structural Rating
194
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
194
Pipe schematic from manhole 18 0092 to 18 0091
MH: 18 0092MH: 18 0091downstream0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 00920 ft. MWL - Water Level, 30 %of cross sectional area6 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start91 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"97.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"213.7 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES226.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"232.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"325.5 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish328.6 ft. AMH - Downstream Manhole, Survey Ends - 18 0091

Observation photos (2)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    6 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

    213.7 ft. - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

Observations (11)

DistanceCodeObservation
0MWM
325.5SAP
91TFC
0AMH18 0092
97.6TFC
328.6AMH18 0091
213.7CL
6SAP
226.7TFC
0MWL
232.9TFC

Properties (5)

custom_field_two
2
customer
LACSD
datetime
2018-07-23T23:32:32-07:00
documentation
PROPIPE
is_lateral_inspection
false